NurslixJournal
降低風險 · EASY · MCQ

護理師照護一位使用密閉式胸腔引流系統的病人。下列何種觀察顯示系統功能正常?

A nurse is caring for a client who has a chest tube connected to a closed-chest drainage system. Which observation indicates the system is functioning correctly?

  • AAbsence of fluid movement in the tubing
    管路中無液體流動
  • BFluctuation of the fluid level in the water-seal chamber✓ 正解
    水封室中液面隨呼吸波動
  • CExcessive drainage in the collection chamber
    收集室中有過多引流液
  • DContinuous bubbling in the water-seal chamber
    水封室中有持續冒泡現象
Explanation · 中文詳解

胸腔引流系統正常運作時,水封瓶液面應隨病人的呼吸運動而上下波動(潮氣現象)。若連續冒泡(D)通常代表系統有漏氣;若完全不動(A)可能代表管路阻塞或肺部已完全擴張;過量引流(C)則需根據臨床狀況判斷,非功能正常的必要條件。

When a chest drainage system is functioning normally, the fluid level in the water-seal chamber should rise and fall with the patient's respirations (tidaling). Continuous bubbling (D) usually indicates an air leak in the system; absence of any movement (A) may indicate a blocked tube or full lung re-expansion; excessive drainage (C) must be interpreted clinically and is not a necessary feature of normal function.

✦ 台美臨床差異

美台皆強調 tidaling,但台灣臨床常需醫師確認是否夾管,美國則依循單位 protocol 處理。

Related · 同分類的其他題目

More from Reduction of Risk Potential

瀏覽全部 1,953 題 降低風險 →
Jump to another chapter