一位接有胸管抽吸裝置的病人,下列哪項觀察結果是正常的且預期的?

A nurse is caring for a client with a chest tube connected to a suction device. Which of the following findings is normal and expected?

  • ABright red drainage of 300 mL in the last hour
    最後一小時內有 300 mL 的鮮紅引流液
  • BAbsence of any drainage in the collection chamber
    收集腔室中沒有任何引流液
  • CFluctuation of the fluid level in the water seal chamber with respiration✓ 正解
    水封腔室中的液面隨呼吸波動
  • DContinuous bubbling in the water seal chamber
    水封腔室中有連續冒泡
Explanation · 中文詳解

胸管水封瓶(water seal)內的液體隨呼吸上下波動(tidaling)是正常的生理表現,代表胸腔內壓與呼吸循環同步。持續性氣泡通常暗示漏氣(air leak),大量鮮血代表出血活動,無排水則可能阻塞。

Fluctuation of the fluid level in the water seal chamber, known as tidaling, is a normal finding that reflects pressure changes in the pleural space during respiration. Continuous bubbling indicates an air leak, bright red drainage suggests active hemorrhage, and absence of drainage may signal a blockage in the tubing.

✦ 台美臨床差異

台美胸管照護原則一致,皆重視水封管的水面波動與氣泡監測,強調安全性指標。